Blog List

Saturday 6 August 2016

Biocide Retention Variation and Gradients in Commercially Treated 4 by 4s

Published Date
February 2010

Author

Schultz, T. P.; Nicholas, Darrel D

Abstract

Biocide retentions for copper-based wood preservatives used for residential ground-contact applications are established through field stake tests using small research stakes cut from selected sapwood and then treated in laboratory cylinders. The results from the relatively short-term field tests are then used to specify retentions for commercially treated timbers that have a range of densities and heartwood content. More than 120 4 by 4s that had been commercially treated with four copper-based systems readily available were purchased, with the posts carefully selected for good biocide penetration and a wide outer sapwood band, and analyzed for biocide retentions. Also, biocide gradients from five soluble copper and three particulate copper commercially treated 4 by 4s, all having the same labeled retention, were determined. All four systems gave a range of analyzed retentions, with some fraction of the timbers of each preservative system having a relatively low biocide level. In contrast to previous reports, the biocide gradient for wood treated with a soluble copper formulation was less steep than in wood treated with a particulate copper system.


For further details log on website :
http://connection.ebscohost.com/c/articles/55069346/biocide-retention-variation-gradients-commercially-treated-4-by-4s

No comments:

Post a Comment

Advantages and Disadvantages of Fasting for Runners

Author BY   ANDREA CESPEDES  Food is fuel, especially for serious runners who need a lot of energy. It may seem counterintuiti...