Published Date
Abstract
In the present paper, the bending behavior of Cross Laminated Timber panels is investigated by means of the linear elastic exact solution from Pagano (1970, 1969). The resulting stresses are the input for a wood failure criterion, which can point out the first-crack load and the respective dominant failure mode. Heterogeneous layers are modeled as equivalent and homogeneous layers. This simplified and deterministic modeling gives results in good agreement with a reference experimental test. A comparison is made with respect to the panel’s global stiffness and failure stages within the apparent elastic stage. Finally, parameter studies are carried out, in order to quantify CLT limitations and advantages. The effect of varying properties such as the panel’s slenderness, orientation of transverse layers and number of layers for a fixed total thickness are investigated.
References
For further details log on website :
http://link.springer.com/article/10.1007/s00107-016-1038-x
, Volume 74, Issue 5, pp 671-684
First online:
Title
Influence of orientation and number of layers on the elastic response and failure modes on CLT floors: modeling and parameter studies
- Author
Abstract
In the present paper, the bending behavior of Cross Laminated Timber panels is investigated by means of the linear elastic exact solution from Pagano (1970, 1969). The resulting stresses are the input for a wood failure criterion, which can point out the first-crack load and the respective dominant failure mode. Heterogeneous layers are modeled as equivalent and homogeneous layers. This simplified and deterministic modeling gives results in good agreement with a reference experimental test. A comparison is made with respect to the panel’s global stiffness and failure stages within the apparent elastic stage. Finally, parameter studies are carried out, in order to quantify CLT limitations and advantages. The effect of varying properties such as the panel’s slenderness, orientation of transverse layers and number of layers for a fixed total thickness are investigated.
References
- Aicher S, Dill-Langer S (2000) Basic considerations to rolling shear modulus in wooden boards. Tech. rep, Otto Graf Journal
- ANSI, APA (2012) ANSI/APA PRG 320–2012 Standards for performance-rated cross-laminated timber. ANSI/APA, Tacoma, US
- Blass H, Fellmoser P (2004a) Design of solid wood panels with cross layers. In: Proocedings of the 8th World Conference on Timber Engineering
- Blass H, Fellmoser P (2004b) Influence of rolling shear modulus on strength and stiffness of structural bonded timber elements. In: International Council for Research and Innovation in Building and Construction, Working Commission W18
- Blass H, Gorlacher R (2000) Rolling shear in structural bonded timber elements. In: International conference on wood and wood fiber composites
- Brandner R, Dietsch P, Droscher J, Shulte-Wrede M, Kreuzinger H, Sieder M, Schickhofer G, Winter S (2015) Shear properties of Cross Laminated Timber (CLT) under in-plane load: test configuration and experimental study. In: Proceedings of the 2nd International Network on Timber Engineering Research meeting
- Cabrero JM, Blanco C, Gebremedhin KG, Martin-Meizoso A (2012) Assessment of phenomenological failure criteria for wood. Eur J Wood Wood Prod 127(6):871–882CrossRef
- Chen Y, Lam F (2013) Bending performance of box-based cross-laminated timber systems. J Struct Eng 139(12):04013006
- Czaderski C, Steiger R, Howald M, Olia S, Gulzow A, Niemz P (2007) Tests and calculations on 3-layered cross-laminated solid wood panels supported at all edges. Holz Roh Werkst 65:383–402CrossRef
- Dahl K (2009) Mechanical properties of clear wood from Norway spruce. PhD thesis, Norwegian University of science and technology
- DIN (2004) DIN 1052:2004 Design rules for timber buildings (in German). German Institute of Standardization, Berlin, Germany
- Eberhardsteiner J (2002) Mechanical behavior of Spruce (in German). Springer, Vienna, Austria
- EN (2004) Eurocode 5 Design of timber structures. Part 1-1: General Common rules and rules for buildings. European Committee for Standardization, CEN, Bruxelles, Belgium
- EN (2009) EN 338: Structural timber - strength classes. European Committee for Standardization, CEN, Bruxelles, Belgium
- ETA (2013) ETA - 06/0009: Binderholz Cross Laminated Timber BBS. Binderholz Bausysteme GmbH, Zillertalstrasse 39 6263 Fugen, Austria
- Gagnon S, Pirvu C (2013) CLT handbook: Cross Laminated Timber. FPInnovations, Qubec, Canada
- Hochreiner G, Fussl J, Eberhardsteiner J (2013) Cross Laminated Timber plates subjected to concentrated loading. Experimental identification of failure mechanisms. Strain 50(1):68–71CrossRef
- Hochreiner G, Fussl J, Serrano E, Eberhardsteiner J (2014) Influence of wooden board strength class on the performance of Cross Laminated Timber plates investigated by means of full-field deformations measurements. Strain 50(2):161–173CrossRef
- Jobstl R, Moosbrugger T, Bogensperger T, Schickhofer G (2006) A contribution to the design and system effect of cross laminated timber (CLT). In: International Council for Research and Innovation in Building and Construction, Working Commission W18
- Keunecke D, Hering S, Niemz P (2008) Three-dimensional elastic behaviour of common yew and Norway spruce. Wood Sci Technol 42(8):633–647CrossRef
- Kirchhoff G (1850) On the equilibrium and kinematics of an elastic plate (in German). J Pure Appl Math 40:51–88
- Kreuzinger H (1999) Plate and shell structures. A model for common calculation tools (in German). Bauen mit Holz 1:34–39
- Lebée A, Sab K (2011) A Bending-Gradient model for thick plates, Part I: Theory. Int J Solid Struct 48:2878–2888CrossRef
- Lebée A, Sab K (2012) Homogenization of thick periodic plates: application of the Bending-Gradient plate theory to a folded core sandwich panel. Int J Solid Struct 49:2778–2792CrossRef
- Lebée A, Sab K (2013) Homogenization of a space frame as a thick plate: Application of the Bending-Gradient theory to a beam lattice. Comput Struct 70:88–101CrossRef
- March HW (1936) Bending of a Centrally Loaded Rectangular Strip of Plywood. Physics (College Park Md) 7(1) DOI 10.1063/1.1745342
- Mestek P (2011) Cross laminated timber panels under concentrated loads: design with local shear reinforcement (in german). PhD thesis, Munich University of Technology
- Mestek P, Kreuzinger H, Winter S (2008) Design of Cross Laminated Timber (CLT). In: Proceedings of the 10th World Conference on Timber Engineering
- Moosbrugger T, Guggenberger W, Bogensperger T (2006) Cross Laminated Timber wall segments under homogeneous shear with and without openings. In: Proceedings of the 9th World Conference on Timber Engineering
- Pagano N (1969) Exact solutions for rectangular bidirectional composites and sandwich plates. J Compos Mater 4:20–34
- Pagano N (1970) Influence of shear coupling in cylindrical bending of anisotropic laminates. J Compos Mater 4:330–343CrossRef
- Schickhofer G, Bogensperger T, Moosbrugger T (2009) CLT Handbook: buildings with Cross Laminated Timber (in German). Technische Universitat Graz, Graz, Austria
- Sebera V, Muszyski L, Tippner J, Noyel M, Pisaneschi T, Sundberg B (2013) FE analysis of CLT panel subjected to torsion and verified by DIC. Materials and Structures 1(9)
- Stapel P, van de Kuilen J-WG (2014) Influence of cross-section and knot assessment on the strength of visually graded Norway spruce. Eur J Wood Prod 72:213–227CrossRef
- Sturzenbecher R, Hofstetter K, Eberhardsteiner J (2010) Structural design of Cross Laminated Timber (CLT) by advanced plate theories. Compos Sci Technol 70:1368–1379CrossRef
- Thai ND, Dottavio M, Caron JF (2013) Bending analysis of laminated and sandwich plates using a layer-wise stress model. Compos Struct 96:135–142CrossRef
- Tsai S, Wu E (1971) A general theory of strength for anisotropic materials. J Compos Mater 5(1):58–80CrossRef
- van der Put T (1982) A general failure criterion for wood. In: Proceedings of 15th Conseil Industriel des Bois-International. Union of Forestry Research Organizations Meeting, Boras, Sweden
- Zhou Q, Gong M, Chui Y, Mohammad M (2014) Measurement of rolling shear modulus and strength of Cross Laminated Timber using bending and two plates shear tests. Wood Fiber Sci 46(2):1–11